Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.771
Filtrar
1.
Methods Mol Biol ; 2794: 33-43, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630218

RESUMO

Two-photon FRET (Förster resonance energy transfer) and FLIM (fluorescence lifetime imaging microscopy) enable the detection of FRET changes of fluorescence reporters in deep brain tissues, which provide a valuable approach for monitoring target molecular dynamics and functions. Here, we describe two-photon FRET and FLIM imaging techniques that allow us to visualize endogenous and optogenetically induced cAMP dynamics in living neurons with genetically engineered FRET-based cAMP reporters.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Engenharia Genética , Microscopia de Fluorescência , Neurônios , Fótons
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 156-159, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605614

RESUMO

Objective: The distribution of the photon energy spectrum in isocenter plane of the medical linear accelerator and the influence of secondary collimator on the photon energy spectrum are studied. Methods Use the BEAMnrc program to simulate the transmission of the 6 MeV electrons and photons in 5 cm×5 cm,10 cm×10 cm,15 cm×15 cm and 20 cm×20 cm fields in treatment head of the medical linear accelerator, where a phase space file was set up at the isocenter plane to record the particle information passing through this plane. The BEAMdp program is used to analyze the phase space file, in order to obtain the distribution of the photon energy spectrum in isocenter plane and the influence of secondary collimator on the photon energy spectrum. Results: By analyzing the photon energy spectrum of a medical linear accelerator with a nominal energy of 6 MV, it is found that the secondary collimator has little effect on the photon energy spectrum; different fields have different photon energy spectrum distributions; the photon energy spectrum in different central regions of the same field have the same normalized distribution. Conclusion: In the dose calculation of radiation therapy, the influence of photon energy spectrum should be carefully considered.


Assuntos
Fótons , Planejamento da Radioterapia Assistida por Computador , Método de Monte Carlo , Fótons/uso terapêutico , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica
3.
Nat Commun ; 15(1): 3192, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609354

RESUMO

Neuronal ensembles are groups of neurons with correlated activity associated with sensory, motor, and behavioral functions. To explore how ensembles encode information, we investigated responses of visual cortical neurons in awake mice using volumetric two-photon calcium imaging during visual stimulation. We identified neuronal ensembles employing an unsupervised model-free algorithm and, besides neurons activated by the visual stimulus (termed "onsemble"), we also find neurons that are specifically inactivated (termed "offsemble"). Offsemble neurons showed faster calcium decay during stimuli, suggesting selective inhibition. In response to visual stimuli, each ensemble (onsemble+offsemble) exhibited small trial-to-trial variability, high orientation selectivity, and superior predictive accuracy for visual stimulus orientation, surpassing the sum of individual neuron activity. Thus, the combined selective activation and inactivation of cortical neurons enhances visual encoding as an emergent and distributed neural code.


Assuntos
Cálcio , Neurônios , Animais , Camundongos , Algoritmos , Inibição Psicológica , Fótons
4.
PLoS One ; 19(4): e0301435, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635642

RESUMO

In radiotherapy, when photon energy exceeding 8 MV is utilized, photoneutrons can activate the components within the gantry of the linear accelerator (linac). At the end of the linac's lifecycle, radiation workers are tasked with its dismantling and disposal, potentially exposing them to unintentional radiation. This study aims to identify and measure the radioisotopes generated by this activation through spectroscopy, and to evaluate the effective dose rate. We selected nine medical linacs, considering various factors such as manufacturer (Siemens, Varian, and Elekta), model, energy, period of operation, and workload. We identified the radionuclides in the linac head by employing an in situ high-purity germanium (HPGe) detector. Spectroscopy and dose-rate measurements were conducted post-shutdown. We also measured the dose rates at the beam-exit window following irradiation with 10 MV and 15 MV photon beams. As a result of the spectroscopy, we identified approximately 20 nuclides including those with half-lives of 100 days or longer, such as 54Mn, 60Co, 65Zn, 122Sb, and 198Au. The dose rate measurements after 10 MV irradiation decreased to the background level in 10 min. By contrast, on 15 MV irradiation, the dose rate was 628 nSv/h after 10 min and decreased to 268 nSv/h after 1.5 hours. It was confirmed that the difference in the level of radiation and the type of nuclide depends on the period of use, energy, and workload. However, the type of nuclide does not differ significantly between the linacs. It is necessary to propose appropriate guidelines for the safety of workers, and disposal/move-install should be planned while taking into consideration the equipment's energy usage rate.


Assuntos
Manganês , Radioisótopos , Humanos , Dosagem Radioterapêutica , Aceleradores de Partículas , Fótons , Análise Espectral
5.
J Biomed Opt ; 29(2): 026004, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38425720

RESUMO

Significance: Fluorescence lifetime imaging (FLI) plays a pivotal role in enhancing our understanding of biological systems, providing a valuable tool for non-invasive exploration of biomolecular and cellular dynamics, both in vitro and in vivo. Its ability to selectively target and multiplex various entities, alongside heightened sensitivity and specificity, offers rapid and cost-effective insights. Aim: Our aim is to investigate the multiplexing capabilities of near-infrared (NIR) FLI within a scattering medium that mimics biological tissues. We strive to develop a comprehensive understanding of FLI's potential for multiplexing diverse targets within a complex, tissue-like environment. Approach: We introduce an innovative Monte Carlo (MC) simulation approach that accurately describes the scattering behavior of fluorescent photons within turbid media. Applying phasor analyses, we enable the multiplexing of distinct targets within a single FLI image. Leveraging the state-of-the-art single-photon avalanche diode (SPAD) time-gated camera, SPAD512S, we conduct experimental wide-field FLI in the NIR regime. Results: Our study demonstrates the successful multiplexing of dual targets within a single FLI image, reaching a depth of 1 cm within tissue-like phantoms. Through our novel MC simulation approach and phasor analyses, we showcase the effectiveness of our methodology in overcoming the challenges posed by scattering media. Conclusions: This research underscores the potential of NIR FLI for multiplexing applications in complex biological environments. By combining advanced simulation techniques with cutting-edge experimental tools, we introduce significant results in the non-invasive exploration of biomolecular dynamics, to advance the field of FLI research.


Assuntos
Imagem Óptica , Fótons , Simulação por Computador , Imagens de Fantasmas , Corantes
6.
Radiology ; 310(3): e231986, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38501953

RESUMO

Photon-counting CT (PCCT) is an emerging advanced CT technology that differs from conventional CT in its ability to directly convert incident x-ray photon energies into electrical signals. The detector design also permits substantial improvements in spatial resolution and radiation dose efficiency and allows for concurrent high-pitch and high-temporal-resolution multienergy imaging. This review summarizes (a) key differences in PCCT image acquisition and image reconstruction compared with conventional CT; (b) early evidence for the clinical benefit of PCCT for high-spatial-resolution diagnostic tasks in thoracic imaging, such as assessment of airway and parenchymal diseases, as well as benefits of high-pitch and multienergy scanning; (c) anticipated radiation dose reduction, depending on the diagnostic task, and increased utility for routine low-dose thoracic CT imaging; (d) adaptations for thoracic imaging in children; (e) potential for further quantitation of thoracic diseases; and (f) limitations and trade-offs. Moreover, important points for conducting and interpreting clinical studies examining the benefit of PCCT relative to conventional CT and integration of PCCT systems into multivendor, multispecialty radiology practices are discussed.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Criança , Humanos , Processamento de Imagem Assistida por Computador , Fótons
7.
Sci Rep ; 14(1): 6343, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491195

RESUMO

The in vivo diagnosis and monitoring of pulmonary disorders (caused for example by emphysema, Covid-19, immature lung tissue in infants) could be effectively supported by the non-invasive sensing of the lung through light. With this purpose, we investigated the feasibility of probing the lung by means of time-resolved diffuse optics, leveraging the increased depth (a few centimeters) attained by photons collected after prolonged propagation time (a few nanoseconds). We present an initial study that includes measurements performed on 5 healthy volunteers during a breathing protocol, using a time-resolved broadband diffuse optical spectroscopy system. Those measurements were carried out across the spectral range of 600-1100 nm at a source-detector distance of 3 cm, and at 820 nm over a longer distance (7-9 cm). The preliminary analysis of the in vivo data with a simplified homogeneous model revealed a maximum probing depth of 2.6-3.9 cm, suitable for reaching the lung. Furthermore, we observed variations in signal associated with respiration, particularly evident at long photon propagation times. However, challenges stemming from both intra- and inter-subject variability, along with inconsistencies potentially arising from conflicting scattering and absorption effects on the collected signal, hindered a clear interpretation. Aspects that require further investigation for a more comprehensive understanding are outlined.


Assuntos
Óptica e Fotônica , Fótons , Humanos , Análise Espectral/métodos , Pulmão/diagnóstico por imagem
8.
Molecules ; 29(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38474592

RESUMO

This article reports three new two-photon absorption (TPA) materials that are quinolinium-carbazole derivates. They are 3-(N-methyl-4-ethylquinolinium iodide)-9-ethylcarbazole (M4), 3-(N-methyl-4-ethylquinolinium iodide)-9-ethylcarbazole (H2), and 3-(N-methyl-4-ethylquinolinium iodide)-9-ethylcarbazole (H4). Their TPA cross-sections are 491, 515, and 512 GM, respectively. Under the excitation of near-infrared light, their fluorescence emission is about 650 nm. The compounds can stain nucleic acid DNA with the same level of nuclear localization as Hoechst 33342. Under continuous irradiation with a near-infrared laser, the three new compounds showed less fluorescence decay than DAPI, and the average fluorescence decay rates were 0.016%/s, 0.020%/s, and 0.023%/s. They are expected to become new two-photon fluorescent probes of nucleic acid DNA because of their excellent performance.


Assuntos
Iodetos , Fótons , Fluorescência , Carbazóis , DNA , Raios Infravermelhos , Sondas de Ácido Nucleico , Corantes Fluorescentes
9.
Comput Biol Med ; 173: 108334, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520919

RESUMO

Hypoxia contributes significantly to resistance in radiotherapy. Our research rigorously examines the influence of microvascular morphology on radiotherapy outcome, specifically focusing on how microvasculature shapes hypoxia within the microenvironment and affects resistance to a standard treatment regimen (30×2GyRBE). Our computational modeling extends to the effects of different radiation sources. For photons and protons, our analysis establishes a clear correlation between hypoxic volume distribution and treatment effectiveness, with vascular density and regularity playing a crucial role in treatment success. On the contrary, carbon ions exhibit distinct effectiveness, even in areas of intense hypoxia and poor vascularization. This finding points to the potential of carbon-based hadron therapy in overcoming hypoxia-induced resistance to RT. Considering that the spatial scale analyzed in this study is closely aligned with that of imaging data voxels, we also address the implications of these findings in a clinical context envisioning the possibility of detecting subvoxel hypoxia.


Assuntos
Hipóxia , Fótons , Humanos , Fótons/uso terapêutico , Carbono
10.
J Am Chem Soc ; 146(12): 8417-8424, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38499198

RESUMO

Photocages enable scientists to take full control over the activity of molecules using light as a biocompatible stimulus. Their emerging applications in photoactivated therapies call for efficient uncaging in the near-infrared (NIR) window, which represents a fundamental challenge. Here, we report synthetically accessible cyanine photocages that liberate alcohol, phenol, amine, and thiol payloads upon irradiation with NIR light up to 820 nm in aqueous media. The photocages display a unique chameleon-like behavior and operate via two distinct uncaging mechanisms: photooxidation and heterolytic bond cleavage. The latter process constitutes the first example of a direct bond scission by a single photon ever observed in cyanine dyes or at wavelengths exceeding 800 nm. Modulation of the beating rates of human cardiomyocytes that we achieved by light-actuated release of adrenergic agonist etilefrine at submicromolar concentrations and low NIR light doses (∼12 J cm-2) highlights the potential of these photocages in biology and medicine.


Assuntos
Fótons , Humanos , Miócitos Cardíacos
11.
Phys Med Biol ; 69(9)2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38537308

RESUMO

Objective.A Monte Carlo virtual source model named PHID (photon from Ion decay) that generates photons emitted in the complex decay chain process of alpha-emitter radionuclides is proposed, typically for use during the simulation of SPECT image acquisition.Approach.Given an alpha-emitter radionuclide, the PHID model extracts from Geant4 databases the photon emission lines from all decaying daughters for both isometric transition and atomic relaxation processes. According to a given time range, abundances and activities in the decay chain are considered thanks to the Bateman equations, taking into account the decay rates and the initial abundances.Main results.PHID is evaluated by comparison with analog Monte Carlo simulation. It generates photons with the correct energy and temporal distribution, avoiding the costly simulation of the complete decay chain thus decreasing the computation time. The exact time gain depends on the simulation setup. As an example, it is 30× faster for simulating 1 MBq of225Ac in water for 1 section Moreover, for225Ac, PHID was also compared to a simplified source model with the two main photon emission lines (218 and 440 keV). PHID shows that 2 times more particles are simulated and 60% more counts are detected in the images.Significance.PHID can simulate any alpha-emitter radionuclide available in the Geant4 database. As a limitation, photons emitted from Bremsstrahlung are ignored, but they represent only 0.7% of the photons above 30 keV and are not significant for SPECT imaging. PHID is open-source, available in GATE 10, and eases the investigation of imaging photon emission from alpha emitters.


Assuntos
Radioisótopos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Simulação por Computador , Fótons , Imagens de Fantasmas , Método de Monte Carlo
12.
Int J Mol Sci ; 25(6)2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38542106

RESUMO

This review describes the two-photon absorption properties of dendrimers, which are arborescent three-dimensional macromolecules differing from polymers by their perfectly defined structure. The two-photon absorption process is a third order non-linear optical property that is attractive because it can be used in a wide range of applications. In this review, dendrimers that were studied for their two-photon absorption properties are first described. Then, the use of dendritic TPA chromophores for light harvesting, photopolymerization, optical power limitation, cell imaging, singlet oxygen generation, and photodynamic therapy is described. This review thus proposes an overview of the properties and possible applications of two-photon absorbing dendrimers.


Assuntos
Dendrímeros , Fotoquimioterapia , Dendrímeros/química , Fármacos Fotossensibilizantes/química , Fotoquimioterapia/métodos , Fótons , Polímeros/química
13.
Phys Med Biol ; 69(8)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38484392

RESUMO

Objective.Monolithic crystal detectors are increasingly being applied in positron emission tomography (PET) devices owing to their excellent depth-of-interaction (DOI) resolution capabilities and high detection efficiency. In this study, we constructed and evaluated a dual-ended readout monolithic crystal detector based on a multiplexing method.Approach.We employed two 12 × 12 silicon photomultiplier (SiPM) arrays for readout, and the signals from the 12 × 12 array were merged into 12 X and 12 Y channels using channel multiplexing. In 2D reconstruction, three methods based on the centre of gravity (COG) were compared, and the concept of thresholds was introduced. Furthermore, a light convolutional neural network (CNN) was employed for testing. To enhance depth localization resolution, we proposed a method by utilizing the mutual information from both ends of the SiPMs. The source width and collimation effect were simulated using GEANT4, and the intrinsic spatial resolution was separated from the measured values.Main results.At an operational voltage of 29 V for the SiPM, an energy resolution of approximately 12.5 % was achieved. By subtracting a 0.8 % threshold from the total energy in every channel, a 2D spatial resolution of approximately 0.90 mm full width at half maximum (FWHM) can be obtained. Furthermore, a higher level of resolution, approximately 0.80 mm FWHM, was achieved using a CNN, with some alleviation of edge effects. With the proposed DOI method, a significant 1.36 mm FWHM average DOI resolution can be achieved. Additionally, it was found that polishing and black coating on the crystal surface yielded smaller edge effects compared to a rough surface with a black coating.Significance.The introduction of a threshold in COG method and a dual-ended readout scheme can lead to excellent spatial resolution for monolithic crystal detectors, which can help to develop PET systems with both high sensitivity and high spatial resolution.


Assuntos
Redes Neurais de Computação , Tomografia por Emissão de Pósitrons , Tomografia por Emissão de Pósitrons/métodos , Fótons , Gravitação
14.
J Biomed Opt ; 29(3): 036501, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38487259

RESUMO

Significance: Label-free nonlinear optical microscopy has become a powerful tool for biomedical research. However, the possible photodamage risk hinders further clinical applications. Aim: To reduce these adverse effects, we constructed a new platform of simultaneous label-free autofluorescence multi-harmonic (SLAM) microscopy, featuring four-channel multimodal imaging, inline photodamage monitoring, and pulse repetition-rate tuning. Approach: Using a large-core birefringent photonic crystal fiber for spectral broadening and a prism compressor for pulse pre-chirping, this system allows users to independently adjust pulse width, repetition rate, and energy, which is useful for optimizing imaging conditions towards no/minimal photodamage. Results: It demonstrates label-free multichannel imaging at one excitation pulse per image pixel and thus paves the way for improving the imaging speed by a faster optical scanner with a low risk of nonlinear photodamage. Moreover, the system grants users the flexibility to autonomously fine-tune repetition rate, pulse width, and average power, free from interference, ensuring the discovery of optimal imaging conditions with high SNR and minimal phototoxicity across various applications. Conclusions: The combination of a stable laser source, independently tunable ultrashort pulse, photodamage monitoring features, and a compact design makes this new system a robust, powerful, and user-friendly imaging platform.


Assuntos
Lasers , Fótons , Microscopia Óptica não Linear , Microscopia de Fluorescência por Excitação Multifotônica/métodos
15.
Phys Med Biol ; 69(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38471186

RESUMO

Following the rapid, but independent, diffusion of x-ray spectral and phase-contrast systems, this work demonstrates the first combination of spectral and phase-contrast computed tomography (CT) obtained by using the edge-illumination technique and a CdTe small-pixel (62µm) spectral detector. A theoretical model is introduced, starting from a standard attenuation-based spectral decomposition and leading to spectral phase-contrast material decomposition. Each step of the model is followed by quantification of accuracy and sensitivity on experimental data of a test phantom containing different solutions with known concentrations. An example of a micro CT application (20µm voxel size) on an iodine-perfusedex vivomurine model is reported. The work demonstrates that spectral-phase contrast combines the advantages of spectral imaging, i.e. high-Zmaterial discrimination capability, and phase-contrast imaging, i.e. soft tissue sensitivity, yielding simultaneously mass density maps of water, calcium, and iodine with an accuracy of 1.1%, 3.5%, and 1.9% (root mean square errors), respectively. Results also show a 9-fold increase in the signal-to-noise ratio of the water channel when compared to standard spectral decomposition. The application to the murine model revealed the potential of the technique in the simultaneous 3D visualization of soft tissue, bone, and vasculature. While being implemented by using a broad spectrum (pink beam) at a synchrotron radiation facility (Elettra, Trieste, Italy), the proposed experimental setup can be readily translated to compact laboratory systems including conventional x-ray tubes.


Assuntos
Compostos de Cádmio , Iodo , Pontos Quânticos , Camundongos , Animais , Iluminação , Fótons , Telúrio , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
16.
Photosynth Res ; 160(1): 31-44, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38502255

RESUMO

Accumulation of carotenoid (Car) triplet states was investigated by singlet-triplet annihilation, measured as chlorophyll (Chl) fluorescence quenching in sunflower and lettuce leaves. The leaves were illuminated by Xe flashes of 4 µs length at half-height and 525-565 or 410-490 nm spectral band, maximum intensity 2 mol quanta m-2 s-1, flash photon dose up to 10 µmol m-2 or 4-10 PSII excitations. Superimposed upon the non-photochemically unquenched Fmd state, fluorescence was strongly quenched near the flash maximum (minimum yield Fe), but returned to the Fmd level after 30-50 µs. The fraction of PSII containing a 3Car in equilibrium with singlet excitation was calculated as Te = (Fmd-Fe)/Fmd. Light dependence of Te was a rectangular hyperbola, whose initial slope and plateau were determined by the quantum yields of triplet formation and annihilation and by the triplet lifetime. The intrinsic lifetime was 9 µs, but it was strongly shortened by the presence of O2. The triplet yield was 0.66 without nonphotochemical quenching (NPQ) but approached zero when NP-Quenched fluorescence approached 0.2 Fmd. The results show that in the Fmd state a light-adapted charge-separated PSIIL state is formed (Sipka et al., The Plant Cell 33:1286-1302, 2021) in which Pheo-P680+ radical pair formation is hindered, and excitation is terminated in the antenna by 3Car formation. The results confirm that there is no excitonic connectivity between PSII units. In the PSIIL state each PSII is individually turned into the NPQ state, where excess excitation is quenched in the antenna without 3Car formation.


Assuntos
Fótons , Complexo de Proteína do Fotossistema II , Carotenoides , Clorofila , Complexos de Proteínas Captadores de Luz
17.
Chem Pharm Bull (Tokyo) ; 72(3): 311-312, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38494724

RESUMO

An improvement of the two-photon excitation was achieved using 8-azacoumarin-type caged compounds, which showed large values of the two-photon uncaging action cross-section (δu >0.1 Goeppert-Mayer (GM)). In particular, the 7-hydroxy-6-iodo-8-azacoumarin (8-aza-Ihc)-caged compound showed an excellent uncaging action cross-section value (δu = 1.28 GM). Therefore, 8-azacoumarin-type photolabile protecting groups (PPGs) can be used as two-photon excitation sources.


Assuntos
Fótons
18.
Phys Chem Chem Phys ; 26(11): 8879-8890, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38426309

RESUMO

Radiation therapy uses ionizing radiation to break chemical bonds in cancer cells, thereby causing DNA damage and leading to cell death. The therapeutic effectiveness can be further increased by making the tumor cells more sensitive to radiation. Here, we investigate the role of the initial halogen atom core hole on the photofragmentation dynamics of 2-bromo-5-iodo-4-nitroimidazole, a potential bifunctional radiosensitizer. Bromine and iodine atoms were included in the molecule to increase the photoionization cross-section of the radiosensitizer at higher photon energies. The fragmentation dynamics of the molecule was studied experimentally in the gas phase using photoelectron-photoion-photoion coincidence spectroscopy and computationally using Born-Oppenheimer molecular dynamics. We observed significant changes between shallow core (I 4d, Br 3d) and deep core (I 3d) ionization in fragment formation and their kinetic energies. Despite the fact, that the ions ejected after deep core ionization have higher kinetic energies, we show that in a cellular environment, the ion spread is not much larger, keeping the damage well-localized.


Assuntos
Iodo , Nitroimidazóis , Raios Ultravioleta , Fótons , Radiação Ionizante
19.
Semin Radiat Oncol ; 34(2): 218-228, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38508786

RESUMO

FLASH is an emerging treatment paradigm in radiotherapy (RT) that utilizes ultra-high dose rates (UHDR; >40 Gy)/s) of radiation delivery. Developing advances in technology support the delivery of UHDR using electron and proton systems, as well as some ion beam units (eg, carbon ions), while methods to achieve UHDR with photons are under investigation. The major advantage of FLASH RT is its ability to increase the therapeutic index for RT by shifting the dose response curve for normal tissue toxicity to higher doses. Numerous preclinical studies have been conducted to date on FLASH RT for murine sarcomas, alongside the investigation of its effects on relevant normal tissues of skin, muscle, and bone. The tumor control achieved by FLASH RT of sarcoma models is indistinguishable from that attained by treatment with standard RT to the same total dose. FLASH's high dose rates are able to mitigate the severity or incidence of RT side effects on normal tissues as evaluated by endpoints ranging from functional sparing to histological damage. Large animal studies and clinical trials of canine patients show evidence of skin sparing by FLASH vs. standard RT, but also caution against delivery of high single doses with FLASH that exceed those safely applied with standard RT. Also, a human clinical trial has shown that FLASH RT can be delivered safely to bone metastasis. Thus, data to date support continued investigations of clinical translation of FLASH RT for the treatment of patients with sarcoma. Toward this purpose, hypofractionated irradiation schemes are being investigated for FLASH effects on sarcoma and relevant normal tissues.


Assuntos
Lesões por Radiação , Radioterapia (Especialidade) , Sarcoma , Humanos , Animais , Cães , Camundongos , Sarcoma/radioterapia , Fótons/uso terapêutico , Hipofracionamento da Dose de Radiação , Dosagem Radioterapêutica
20.
Proc Natl Acad Sci U S A ; 121(11): e2313743121, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38446851

RESUMO

In order to deal with a complex environment, animals form a diverse range of neural representations that vary across cortical areas, ranging from largely unimodal sensory input to higher-order representations of goals, outcomes, and motivation. The developmental origin of this diversity is currently unclear, as representations could arise through processes that are already area-specific from the earliest developmental stages or alternatively, they could emerge from an initially common functional organization shared across areas. Here, we use spontaneous activity recorded with two-photon and widefield calcium imaging to reveal the functional organization across the early developing cortex in ferrets, a species with a well-characterized columnar organization and modular structure of spontaneous activity in the visual cortex. We find that in animals 7 to 14 d prior to eye-opening and ear canal opening, spontaneous activity in both sensory areas (auditory and somatosensory cortex, A1 and S1, respectively), and association areas (posterior parietal and prefrontal cortex, PPC and PFC, respectively) showed an organized and modular structure that is highly similar to the organization in V1. In all cortical areas, this modular activity was distributed across the cortical surface, forming functional networks that exhibit millimeter-scale correlations. Moreover, this modular structure was evident in highly coherent spontaneous activity at the cellular level, with strong correlations among local populations of neurons apparent in all cortical areas examined. Together, our results demonstrate a common distributed and modular organization across the cortex during early development, suggesting that diverse cortical representations develop initially according to similar design principles.


Assuntos
Cálcio da Dieta , Furões , Animais , Motivação , Neurônios , Fótons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...